Coimbatore
+919787373621

cooling tower

6814772a5d263414004dd4a4 Card 2

product image
NATURAL DRAFT COOLING TOWER

Fan less cooling tower is function that without driven motor and fan . Its naturally cooling process towers . Hot Water comes from the processing area input to pipe at the top area . Water will be spraying at high velocity stream in some circumferential area . So water goes to sprayed downwardly .Here cooling tower range and approach formulae was applicable. Sometimes water flow will be higher ,cooling range was extremely good and otherwise have cooling range is normal . Baffles Cooling Systems , Fanless cooling tower made up of Maximum covered with FRP louver . FRP ( Fibre reinforcement Plastics ) has been very strength compare than steel plates. We have experienced design team analyze the tower size , Cooling tower approach , Cooling tower range , Cooling tower performance etc., Structural will be made of 100 % Galvanized . So all the seasons ,material will not affected. Main advantage of this cooling tower No fan . So don’t need driving motor .Its hot water cooling by atmospheric air . Nozzle provide at the top of the area on typically. We offered Natural Draft Major Spare parts :  FRP Louver  Galvanized Structural Steels  SS Fasteners  Nozzle Pipes  Spraying Nozzles Applications :  Oil Refineries Plants  Chemical Plants  Petrochemical Plants  Thermal Power Stations  HVAC Industries

6814772a5d263414004dd4a4 Card 2

product image
Dry cooling tower

Dry cooling tower is one of the moderate cooling tower. Nowadays customer preferred in this type of cooling tower . Textiles ,Leather , footwear and clothing sectors its very used for in this type cooling tower . Its main advantage is no more water subsequently for continues processing. So need of water requirement is very low compare than other cooling towers and not comes water moisture from coil. Dry cooling tower is made up of no of wounded coil . Coil has designed based on the technical specifications like flow rate and temperature . Coil tube material is copper tube , Stainless steel ( 304 series) and brass tubes .Copper tubes has been bend at the two side of the corner . In this particular bending area make radius form, so water goes to passing continuously without interruption. All the tube connected area must welded by brazing . All the welding done by qualified welders only . Finns are wrapped on the tubes . Finns wrapped based on heat transfer area .So cooling performance will be very high . Dry Cooling tower Features : • Coil mounted on the ISO standard channels . Coils connected with parallel and serial. • Fan and Motor mounted on the top of the frame. Fan has been dynamic balanced with motor rotation of RPM. • After manufacturing coil , BCS would be conducted hydro pressure test for found any leakage on the coil tubes. • Tube bending joints welded by brazed by qualified welders.In this bended area thinning calculated for min thickness at the particular area. • Frames and sheet metal works has been powder coated. • In suction of air passing side fixed grid for security for finns . At the top of the area motor side fixed bird screen grid . • Inlet and Outlet Nozzle are welded with coil , after welding area examined by NDE ( Penetrate test ) . • Hydro pressure test conducted after assembled the cooling tower at 21 kg/cm² ( 300 psi ) . • No need more water consumption . Application area of the DRY COOLING TOWER :  TEXTILE MILLS  KNITTING COMPANY  TARN & THREAD COMPANYS  PRINTING COMPANY  FABRIC  HOSPITALS  MALLS ,THEATRES Data requirement for design construction : • FLOW RATE ( LPM) • INLET TEMPERATURE ( °C ) • OUTLET TEMPERATURE ( °C ) • DBT (°C )

6814772a5d263414004dd4a4 Card 2

product image
Cooling Tower

Product Details: Type Induced Draft Type, Forced Draft Type Tower Material Wooden, FRP Baffles cooling Systems to dedicate and specialized design for TIMBER COOLING TOWER . We have make new Timber cooling tower as per the customer requirement specification. Our design teams analyze and calculate the process design and parameters by using Thermal engineering and Psychrometric calculation for better performance . Pipe flow analyze and structural making by using software. We have introduce form one single cell to multi cell passing based on the water flow rate and temperature and Size of the area .

Subcategory Tags

Acoustic Enclosure Industrial Silencer Steam Vent Silencer Cooling Tower Wooden Cooling Tower Heat Exchanger Air Cooled Heat Exchanger Shell & Tube Heat Exchanger Pressure Vessels Horizontal Pressure Vessels Storage Tank Chemical Storage Tank Product Details: Brand Color BCS Yes Installation High Pressure Pressure Range (psi) Temperature Range UPTO 600 DEG C Power Consumption (KW) Mild Steel, Full Stainless Steel 304 / 316 Grade, Warranty 4 KW, 3 KW, 2 KW, 1 KW Automation Grade Semi Automatic, Fully Automatic, Manual Shape Autoclave Horizontal Chamber Volume (Litre) No. of Trays Insulation Wall 20-25 Litre Material Single Wall, Double Wall 2 YEARS 1 Tray, 2 Tray, 3 Tray CUSTOMIZED Plate Heat Exchanger Brazed Plate Heat Exchanger - BPHE Removable Heat Exchanger After Coolers Food Processing Industry Heat Exchanger Heat Exchanger manufacturer in Coimbatore Small Heat Exchanger U Tube Bundle Heat Exchanger Finned Tube Heat Exchanger Inter Cooler SS Heat Exchanger Refinery Heat Exchanger Sewage Treatment MS Tube Heat Exchanger Sugar Plant Air Cooled Heat Exchanger Plate Type Heat Exchanger Heat Exchangers Kettle Reboiler U Tube Heat Exchanger Stainless Steel Heat Exchangers Double Pipe Heat Exchanger Dry Heat Exchanger Tubular Heat Exchanger Insulated Heat Exchangers NATURAL DRAFT COOLING TOWER fan less cooling tower Dry cooling tower vent silencer manufacturer Blow off/ Blow down silencer manufacturer vent silencer suppiler Natural gas vent silencer Natural gas vent silencer manufacturer gas vent silencer compressor silencer manufacture blower silencer manufacture centrifugal compressor silencer Turbine warm up silencer manufacturer turbine silencer manufacturer warm up silencer manufacturer fan silencer manufacturer centrifugal fan silencer Autoclave steam vent silencer manufacturer condenser manufacturer in Coimbatore, water cooled duct silencer manufacturer baffle manufacturer splitter manufacturer
Phone Number

+919787373621

Email Address info@bcsind.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address 12/159, UDAYAGOUNDER MEDU, OPP : LAKSHMI NAGAR, MADUKARAI MARKET, COIMBATORE, TAMILNADU

Coimbatore, India, 641105